Reception and control device vers-pk2p. Control and receiving device vers-pk2p Device vers 2

The VERS-PK2P receiving and control device is designed to monitor the status of alarm loops (AL) with security or fire detectors connected to it, issue FIRE, ALARM, FAULT notifications on the output relays of the monitoring station, control sound, light, voice annunciators, “EXIT” display, connected to the notification outputs. Monitors the serviceability of the sounder connection lines and transmits notifications to the “VERS-RS” event recorder connected to the device and to the “VERS-BRU” output relay block

Application area:

  • Providing autonomous and centralized security against intrusion and fire protection at sites, organizing warning systems and controlling technological equipment

Key Features:

  • Distribution of alarm systems into groups for general control of arming/disarming. Each AL group has its own monitoring station relay;
  • Built-in redundant power supply. The VERS-PK2P versions use a battery with a capacity of 4.5 Ah
  • Automatic switching to battery power when the 220V mains voltage is lost, and when mains voltage is available, ensuring its charge. The transition is carried out with the corresponding indication turned on and without issuing false notifications to external circuits. Protection against deep battery discharge;
  • Increased reliability of fire detection (re-querying the status of fire detectors when a FIRE notification is received);
  • Ensuring the operation of the first alarm system (if it is a security alarm) using the “closed door” tactic with a delay of arming for a period of 60 s. If the first alarm zone is violated, the sound notification is activated with a delay of 15 seconds;
  • Touch Memory key management;
  • Execution in plastic and metal housing.

Specifications:

Parameter

Meaning

VERS-PK2P

Number of alarm loops connected to the device 2

Device power

- from an alternating current network with a frequency (50 + 1) Hz, V 220+10%- 25%
- from battery, V 12+ 15%
Voltage supplied by the device to an external load, V 12+ 2
Operating time of the device from the battery during a power outage, hour, not less
-in standby mode without external load on the 12V circuit 24
-in alarm mode at full load on the 12V circuit 5
Battery voltage at which the indication turns on
discharge (flashing LED "12V" and extinguishing LEDs ShS), V
10
Voltage at the terminals for connecting the ShS, V
in standby mode 19+ 1,5
when the loop is open 24+ 3
Leakage resistance between AL wires, kOhm, not less than:
for security alarm 20
for firefighter AL 50
Remote resistor resistance, kOhm 7,5
Maximum resistance of the AL without taking into account the resistance of the remote element. Om, no more 220
Response time to loop violation, ms 300
dimensions 350x140x100
Operating temperature range

30 - +55 °C without battery

VERS-PK 2 TRIO-M version 3.2 is an auto-dial security and monitoring system designed for organizing security against unauthorized persons, fire alarms and notifications at facilities. The system automatically informs users about the status of the object by voice messages and/or SMS messages transmitted to phones via the GSM network (using the main or backup SIM card) and/or via a wired telephone network (TTN).

VERS-PK2 TRIO-M devices Version 3.2 retain full continuity with VERS-PK2 TRIO-M devices in functionality and connection diagram, but have a number of advantages:

  • A highly efficient switching power supply has been introduced;
  • The range of operating mains voltage has been expanded - 135-242 V;
  • Full operation is supported with a deeply discharged battery;
  • The device is equipped with a built-in USB interface for downloading and reading the configuration;
  • Specific gravity has been reduced.

Key Features:

  • Transmitting notifications to the user to 72 programmed phone numbers (GSM, GTS) in the form of voice messages and SMS messages.
  • Number of dial-up numbers:
    • GTS – 24
    • GSM – 24
    • GSM SMS - 24
  • Installation and use of two SIM cards to reserve dialing channels and increase system reliability;
  • GSM signal jamming control. Automatic transition to using a second SIM card with registration of the event in non-volatile memory and transmission of the corresponding message;
  • Monitoring the serviceability of the GTS communication line;
  • Automatic balance control on used SIM cards;
  • Remote control of the alarm loop of devices, querying the alarm loop status with protection from unauthorized access by password and white list (list of phone numbers allowed for communication).
  • Remote and scheduled control of three user relays, (250V, 5A);
  • Built-in event recorder for 3000 records;
  • The duration of one call attempt is 60 seconds;
  • The maximum number of dialing attempts for each GTS or GSM number is 3;
  • Selecting groups of events for which messages are transmitted: arming/disarming, alarm, fire, attention, maintenance, power mode, battery status, GSM account status, temperature status;
  • Possibility of transmitting messages about the status of one or several alarm systems to specific phone numbers;
  • Automated SIM card marking for MAD configuration from an external phone (writing a template to the SIM card with an indication of the recording process) and setting the initial configuration for the auto-dial module;
  • Possibility of manual configuration of device parameters using its built-in controls;
  • Possibility of configuring the device and the auto-dial module using the VERS Configurator computer program via a USB interface;
  • Possibility of mandatory (unconditional) dialing to several phones from general list;
  • Ability to select groups of transmitted messages for each outgoing telephone number;
  • Setting by the user his own SMS texts for messages transmitted by the device on the events of ALARM, FIRE, TECHNOLOGICAL FAILURE;
  • Transmitting the full name of the owner of the Touch Memory key in SMS for events of setting/removing the SSO using Touch Memory keys;
  • Selecting a voice for notification from 6 preset ones in the VERS Configurator program or creating your own voice notifications;
  • Temperature control using an external plug-in sensor “VERS-T” with the possibility of automatic notification or notification upon request of the current state;
  • Monitoring the acoustic environment using an external plug-in “TRIO Active Microphone”.

Specifications:

Number of telephone numbers programmed for notifications

Number of message groups

Number of typical messages

Number of alarm loops connected to the device depending on the version, pcs.

Device power:

From AC mains with frequency (50±1) Hz, V

From battery, V

Maximum power consumed by the device from the AC mains, VA, no more

Maximum current consumed by the device in standby mode from the internal backup battery in the event of a power failure, A, no more

Voltage supplied by the device to an external load, V

Total current of the external load of the device along the 12V circuit (without battery), A, no more

VERS-PK 2/4 TRIO-M

VERS-PK 8 TRIO-M

Maximum external load current of the device on a 12V circuit (if there is a battery or external RIP), A, no more

Voltage at terminals for AL, in standby mode, V

Maximum number of TM keys recorded in the device, pcs.

Number of sections for combining alarm system, up toAsk a specialist a question about VERS-PK2 TRIO-M version 3.2 Security and fire alarm control panel

Question from: Dmitry

1. What is the maximum distance from the device to the touch memory reader?2. What is the maximum distance from the device to the remote microphone?

  • Answered by: Kuzmin Boris Hello, the TM route according to the documents is up to 15m. But in fact, focus on 8m. Trio microphone connecting wire length 200mm.
  • Purpose:
    VERS-PK2 Version 3.1 devices are universal devices that provide intrusion protection, fire protection, access control, light and sound warning at sites. The device can be used both autonomously and as part of centralized security systems.

    Performs the following functions:
    Monitoring the status of alarm loops (AL) with security, fire or process detectors connected to them;
    Issuance of FIRE, ALARM, FAULT notifications on 3 output relays of the monitoring station;
    Control of sound, light, speech annunciators, “EXIT” displays connected to the notification outputs;
    Control of passage through one access point;
    Monitoring of siren connection lines;
    Transmission of notifications to the event recorder VERS-RS version 3.1, output relay block VERS-BRU version 3.1, key block VERS-BK connected to the device via the RS-485 interface;

    Features and Features:
    Number of alarm loops connected to the device depending on the version, pcs: 2
    Flexible programming of up to 36 device and AL parameters;
    Three types of alarm systems: “Fireman”, “Security” and “Technological”;
    Consolidation of alarm systems into sections for general management;
    Alarm control with electronic keys (up to 255 keys);
    Controlling the door lock, ensuring access using access keys;
    Built-in redundant power supply with 4.5Ah battery;
    Possibility of connecting external RIP;
    12 V outputs and outputs to sirens with electronic protection against short circuit and overload, protection against power supply overloads, protection against impulse noise via AL;
    Execution in plastic cases;
    Connecting external units via RS-485.

    The built-in RS-485 interface controller ensures operation of the device with external connected devices “VERS-BRU version 3.1.”, “VERS-RS version 3.1.”, “VERS-BK”. When working via this interface, constant two-way data exchange with devices is carried out: the device transmits information about current events to relay blocks and recorders. And the relay blocks and recorders, in turn, transmit data to the device about their presence in the network. The RS-485 interface allows you to organize parallel operation of several VERS-BRU relay blocks version 3.1. and/or VERS-RS version 3.1.

    Buy VERS "VERS-PK" 2P version 3.1 from Layta at an attractive price. VERS "VERS-PK" 2P version 3.1: description, characteristics, customer reviews, photographs and related products..

    Characteristics of VERS "VERS-PK" 2P version 3.1:

    Manufacturer VERS Basic unit pcs Number of connected ALs 2 Supply voltage, V 220AC Relative air humidity without condensation (operating condition) 0 - 98%

    The description of the product presented is for reference only and may differ from the manufacturer's technical documentation. We advise you to check the availability of the features and functionality you have selected when placing your order. If you find deviations in the description, you can always report this by noting the error and pressing the SHIFT + ENTER keyboard buttons

    Specifications

    • Manufacturer VERS
    • Number of loops 2
    • Alarm current in standby mode, mA 3
    • Number of relay outputs (for monitoring stations, etc.) 2
    • Built-in siren Eat
    • External network supply voltage, V 220
    • Built-in IRP (power supply 220V) Eat
    • Battery capacity, Ah 4.5
    • Current consumption in standby mode, mA no more than 180
    • Dimensions, mm 290x135x90
    • Operating temperature range (without battery), °C) from -30 to +50

    Description

    VERS-PK Version 3.2 devices retain full continuity with VERS-PK Version 3.1 devices in functionality and connection diagram, but have a number of advantages:

    A highly efficient switching power supply has been introduced;
    The range of operating mains voltage has been expanded - 135-242 V;
    Full operation is supported with a deeply discharged battery;
    The device is equipped with a built-in USB interface for downloading and reading the configuration;
    New software for configuring the device has been developed - VERS-PK Prog;
    Specific gravity has been reduced.

    Application area:
    - number of controlled loops - 2;
    - to protect objects from penetration as a security guard;
    - to protect objects from fire as a firefighter;
    - to protect objects from penetration and from fire as a security and firefighter;
    - to control technological equipment in fire extinguishing and smoke removal systems.
    Peculiarities:
    Built-in backup power supply.
    When installing a 12V4 Ah battery (in versions -PK16, -PK24 - 7 Ah), the device will operate for 24 hours.
    When the battery is discharged to 10 V (in the absence of a network), the device automatically turns off the power to energy-consuming circuits in order to prevent deep discharge of the battery and extend its service life.
    Separation of FIRE and ATTENTION signals when using heat or smoke fire detectors in a loop.
    Compatible with all types of sensors, both passive and active.
    Each loop provides power to current-consuming detectors with a current of up to 3 mA.
    In the event of a complete power failure, the VERS-PK device remembers information on all channels and, when power is restored, ensures that notifications are resumed.
    Output for light and sound annunciators with an operating voltage of 12 V.
    Delivery of 12 V voltage to an external load with a current of up to 0.5 A.
    All monitored channels are divided into AL groups (2 groups).
    Each group of alarm loops (alarm loops) can be programmed by the customer with both security and fire functions.
    Controls are protected from unauthorized access.

    The device provides:
    - monitoring the status of alarm loops (AL) with security or fire detectors installed in them.
    - issuing alarm notifications FIRE, ALARM, FAILURE to the monitoring station relay outputs.
    - control of sound, light, speech annunciators, displays connected to the notification outputs.
    - monitoring the serviceability of siren connection lines.
    - transmission of notifications to the VERS-RS event recorder connected to the device and to the VERS-BRU output relay block.
    - configuration of 20 parameters of the device and AL.

    Peculiarities:
    Simple configuration of device parameters and alarm loop using the device itself.
    Various tactics for security and fire alarm systems.
    Increased load capacity for fire alarms. Detector supply current from AL to 2.85 mA.
    Combining alarm systems into groups for general control of arming/disarming alarm systems.
    Alarm control with electronic keys.
    A built-in redundant power supply with a 4.5 Ah battery ensures autonomous operation of the device in standby mode for at least 30 hours.
    Built-in protocol for transmitting notifications to the VERS-RS event recorder and the VERS-BRU relay expansion unit.
    Organization of voice notification together with the speech notification system "RITM".





    Description VERS-PK 2P version 3.2

    The fire and security alarm and control device VERS-PK 2P version 3.2, plastic case, is a universal device that provides intrusion protection, fire protection, access control, light and sound warnings at sites. The device can be used both autonomously and as part of centralized security systems. The VERS-PK 2P version 3.2 devices retain full continuity with the VERS-PK2 Version 3.1 devices in terms of functionality and connection diagram, but have a number of advantages:
    • A highly efficient switching power supply has been introduced;
    • The range of operating mains voltage has been expanded - 135-242 V;
    • Full operation is supported with a deeply discharged battery;
    • The device is equipped with a built-in USB interface for downloading and reading configuration
    • New software for configuring the device has been developed - VERS-PK Prog;
    • Specific gravity has been reduced.
    VERS-PK 2P version 3.2 performs the following functions:
    • Monitoring the status of alarm loops (AL) with security, fire or process detectors connected to them;
    • Issuance of FIRE, ALARM, FAULT notifications on 3 output relays of the monitoring station;
    • Control of sound, light, speech annunciators, “EXIT” displays connected to the notification outputs;
    • Control of passage through one access point;
    • Monitoring of siren connection lines;
    • Transmission of notifications to the event recorder VERS-RS version 3.1, output relay block VERS-BRU version 3.1, key block VERS-BK, VERS-BMK connected to the device via the RS-485 interface;
    Capabilities and features of VERS-PK 2P version 3.2
    • Flexible programming of up to 36 device and AL parameters;
    • Three types of alarm systems: “Fireman”, “Security” and “Technological”;
    • Consolidation of alarm systems into sections for general management;
    • Alarm control with electronic keys (up to 255 keys);
    • Controlling the door lock, ensuring access using access keys;
    • Built-in redundant power supply with 4.5Ah battery;
    • Possibility of connecting external RIP;
    • 12 V outputs and outputs to sirens with electronic protection against short circuit and overload, protection against power supply overloads, protection against impulse noise via AL;
    • Execution in plastic and metal cases;
    • Connecting external units via RS-485.
    The built-in RS-485 interface controller ensures operation of the device with external connected devices “VERS-BRU version 3.1.”, “VERS-RS version 3.1.”, “VERS-BK”, “VERS-BMK”. When working via this interface, constant two-way data exchange with devices is carried out: the device transmits information about current events to relay blocks and recorders. And the relay blocks and recorders, in turn, transmit data to the device about their presence in the network. The RS-485 interface allows you to organize parallel operation of several VERS-BRU relay blocks version 3.1. and/or VERS-RS version 3.1, VERS-BK, VERS-BMK. Security alarm tactics:
    • "With exit and entry delay";
    • "Delay with open door";
    • "Silent alarm";
    • "Auto arm";
    • "Anxious";
    • "24/7"
    • "Disabled state control".
    Firefighter tactics:
    • AL with increased load capacity (increased standby current to 2.85 mA);
    • Single-threshold and two-threshold modes of polling detectors;
    • Verification algorithm (re-survey);
    • Programming the fire detector recovery delay when re-interrogating the state of fire detectors in the AL;
    • "Auto arm";
    • "24 hours a day."

    Technical characteristics of VERS-PK 2P version 3.2

    • Unit: 1 piece
    • Dimensions (mm): 240x200x83.5
    • Weight (kg): 0.90
    • Number of alarm loops connected to the device depending on the version, pcs 2Device power supply:
    • from AC mains with frequency (50±1) Hz, V 135 - 242
    • from battery, V 12 ± 15%
    • Maximum power consumed by the device from the AC mains, VA, no more than 12
    • Maximum current consumed by the device in standby mode from the internal backup battery in the event of a power failure, A, no more than 0.16
    • Voltage supplied by the device to an external load, V 12±2
    • The total current of the external load of the device along the 12V circuit (without battery), A not more than 0.25
    • Maximum external load current of the device via a 12V circuit (if there is a battery or external RIP) A, no more than: 1.2
    • Voltage at the terminals for connecting the AL, in standby mode, V 17±1.7
    • Maximum number of TM keys recorded in the device, pcs. 255
    • Number of AL association groups (sections): 4 Monitoring station output switching parameters:
    • AC voltage no more than, V 120
    • DC voltage, no more than, V 24
    • current, no more than, A 2 Operating conditions:
    • temperature range, °C -30…+50
    • relative air humidity at ambient temperature 25 °C, % 98%